ISO 22514 Vitamin B6 Analysis in Infant Formula
The analysis of vitamin B6 (pyridoxine, pyridoxal, and pyridoxamine) levels in infant formula is critical for ensuring product safety and compliance with international standards. This service provides comprehensive testing according to ISO 22514, which ensures that the nutritional content of infant formula meets stringent requirements.
The significance of vitamin B6 cannot be overstated; it plays a vital role in amino acid metabolism, neurotransmitter synthesis, and immune function. Ensuring accurate levels of vitamin B6 is essential for supporting infant growth and development. This service not only measures the presence but also ensures that the levels are within safe and recommended ranges.
The testing process involves several steps to ensure accuracy and precision. Initially, a representative sample of the infant formula is taken and prepared according to standard laboratory procedures. The preparation method may include extraction techniques such as acid hydrolysis or enzymatic digestion followed by derivatization if necessary. Once the sample has been properly prepared, it undergoes quantitative analysis using high-performance liquid chromatography (HPLC) with fluorescence detection.
During this process, several factors must be controlled to ensure reliable results: pH levels, temperature, and reagent purity. The choice of HPLC column and mobile phase can significantly affect the outcome, so these parameters are carefully selected based on previous validation studies. Additionally, quality control measures include regular calibration of instruments and participation in proficiency testing programs recognized by relevant authorities.
The results obtained from this analysis provide valuable insights into whether the product complies with specified limits set forth by ISO 22514. Compliance is crucial not only for maintaining public trust but also to avoid potential legal issues or recalls due to non-compliance.
Moreover, understanding how vitamin B6 interacts within an infant’s body helps formulate optimal concentrations that support healthy development without causing any adverse effects. By adhering strictly to ISO 22514 standards during this testing process, we ensure that every batch of infant formula undergoes rigorous quality control checks before reaching consumers.
Our commitment to excellence extends beyond just meeting regulatory requirements; it encompasses continuous improvement through cutting-edge technology and methodologies. We stay updated with the latest scientific advancements in nutrition science so as to provide accurate and reliable results.
Scope and Methodology
Sample Preparation: | Precise sample preparation ensures accurate measurement of vitamin B6 content. Samples are typically prepared using acid hydrolysis followed by derivatization if necessary. |
---|---|
Instrumentation: | High-performance liquid chromatography (HPLC) equipped with fluorescence detection is used for quantification. |
Calibration: | Certified standards and regular instrument calibration are essential to maintain precision throughout the analytical process. |
Quality Control: | Participation in internationally recognized proficiency testing programs ensures consistent results across different batches and facilities. |
---|---|
Reporting: | Detailed reports are provided including raw data, calculated values, and compliance status relative to ISO 22514 specifications. |
The methodology described above is designed to meet the rigorous demands of ISO 22514 while ensuring that each analysis adheres strictly to industry best practices. By following these standardized procedures, we guarantee accurate and reliable results every time.
Eurolab Advantages
At Eurolab, our expertise in vitamin B6 analysis for infant formula goes beyond mere compliance with ISO 22514. Our team of highly skilled professionals combines years of experience with state-of-the-art facilities to deliver unparalleled service and support.
- Accurate Results: Leveraging advanced technologies like HPLC ensures precise measurements that are crucial for meeting regulatory requirements.
- Comprehensive Reporting: In addition to numerical data, detailed reports provide interpretation and recommendations based on findings.
- Rapid Turnaround: We understand the importance of timely results in maintaining supply chains. Therefore, we strive to deliver quick turnaround times without compromising quality.
- Customer Support: Our dedicated customer service representatives are always available to assist with any queries or concerns you may have regarding our services.
Choose Eurolab for your vitamin B6 analysis needs in infant formula. Trust us to provide reliable, accurate, and compliant results that exceed expectations.
International Acceptance and Recognition
- ISO 22514: This international standard is widely accepted in countries around the world as it sets stringent limits for vitamin B6 content in infant formula.
- ASTM E3093: Although not directly related to vitamin B6, this American Society for Testing and Materials standard provides guidelines on analytical methods which can be applied when analyzing similar nutritional components.
The acceptance of these standards is reflected in their widespread adoption by regulatory bodies globally. Compliance with such internationally recognized standards ensures that your product meets the highest quality benchmarks.