The AOAC International standard method 991.20 is widely recognized as a robust and reliable procedure for the detection of milk allergens, particularly casein and whey proteins, in food products such as chocolate. This service is crucial for companies that must ensure their products are free from undeclared milk allergens to meet regulatory requirements and consumer expectations.

Chocolate, being a complex matrix composed of cocoa solids, sugar, fats, and various additives, presents unique challenges when it comes to detecting milk allergens. The presence of milk can cause severe allergic reactions in individuals with lactose intolerance or milk allergies. Therefore, the accurate identification and quantification of milk proteins are essential.

The AOAC 991.20 method employs a combination of solid-phase extraction followed by immunoassay-based detection to quantify milk allergens in chocolate samples. This approach ensures high specificity and sensitivity, making it suitable for trace level detections required in compliance with food safety regulations.

Our laboratory adheres strictly to the AOAC 991.20 methodology, ensuring that every analysis is conducted under controlled conditions to maintain accuracy and precision. The method involves several critical steps:

  • Solid-phase extraction of milk allergens from chocolate samples.
  • Dissolution of the extracted allergens in a suitable buffer solution for immunoassay.
  • Immunoassay-based detection using specific antibodies against casein and whey proteins.
  • Quantification of the detected allergens based on standard curves generated during method validation.

The result is provided as the concentration of milk allergens (casein and/or whey) in parts per million (ppm), which helps our clients understand the level of milk present in their chocolate products. This information is invaluable for quality control, product labeling, and ensuring compliance with international food safety standards.

Given the complexity of the chocolate matrix, it is essential to follow precise sample preparation procedures. Typically, samples are ground into a fine powder using a laboratory mill before extraction. The method also requires accurate weighing and homogenization steps to ensure reproducibility of results. Our experienced staff ensures that each step in the process meets the stringent requirements specified by AOAC 991.20.

The AOAC 991.20 method has been validated for a wide range of chocolate products, including milk chocolate, dark chocolate, and white chocolate. This versatility makes it an ideal choice for companies operating across different segments within the confectionery industry. Our laboratory's proficiency in this area allows us to deliver consistent and reliable results, which is critical for maintaining brand integrity and consumer trust.

The method’s accuracy and reliability are further enhanced by our state-of-the-art facilities and experienced technical staff. We ensure that all samples are handled with utmost care, from receipt through analysis to reporting. Our commitment to excellence is reflected in the precision of our results, which can be trusted as a key factor in maintaining product safety and compliance.

The AOAC 991.20 method is particularly important for companies involved in the chocolate manufacturing process. By detecting milk allergens at trace levels, this method helps prevent the risk of cross-contamination during production. This ensures that products are safe for consumers with milk allergies or lactose intolerance. Additionally, it supports accurate labeling and helps maintain consumer confidence.

In conclusion, AOAC 991.20 is a vital tool in the chocolate industry, providing a reliable means to detect milk allergens. Our laboratory's expertise and adherence to this standard ensure that clients receive accurate, reproducible results, which are essential for maintaining product safety and compliance with international food safety regulations.

Applied Standards

The AOAC 991.20 method is based on the principles outlined in AOAC International's standard methods for the analysis of milk allergens in food products. This method has been rigorously validated and is widely recognized for its accuracy and reliability in detecting milk casein and whey proteins.

The primary advantage of using AOAC 991.20 is its ability to quantify milk allergens at trace levels, which is particularly important for chocolate manufacturers who must ensure their products are free from undeclared milk allergens. This method provides a robust framework for detecting these allergens in complex matrices like chocolate, ensuring that the results are accurate and reproducible.

The AOAC 991.20 method has been validated against various types of chocolate samples, including milk chocolate, dark chocolate, and white chocolate. The method’s versatility allows it to be applied across different segments within the confectionery industry, providing consistent and reliable results regardless of the product type.

By adhering to this standard, our laboratory ensures that every analysis conducted is in line with internationally recognized best practices. This commitment to excellence is reflected in the precision and accuracy of our results, which are crucial for maintaining product safety and compliance with international food safety regulations.

Scope and Methodology

Step Description Details
Solid-phase Extraction (SPE) Extraction of milk allergens from chocolate samples. Utilizing aminopropyl silica-based sorbent cartridges for efficient extraction.
Dissolution Dissolving the extracted allergens in buffer solution. Using phosphate-buffered saline (PBS) at pH 7.4.
Immunoassay Detection Detecting milk casein and whey proteins using specific antibodies. The assay employs a sandwich ELISA format with horseradish peroxidase-labeled secondary antibodies for detection.
Quantification Quantifying the detected allergens based on standard curves. Standard curves generated during method validation are used to calculate concentrations of milk allergens in parts per million (ppm).
Data Analysis and Reporting Analyzing results and generating detailed reports for clients. The final report includes sample identification, detection limits, and compliance status based on specified regulatory requirements.

The AOAC 991.20 method is designed to be adaptable to various chocolate samples, ensuring consistent results across different product types. By following these steps meticulously, we ensure that each analysis adheres strictly to the standard, providing reliable and accurate results.

Our laboratory's expertise in this area allows us to deliver consistent and reliable results, which are essential for maintaining product safety and compliance with international food safety regulations. The precision of our methods is further enhanced by our state-of-the-art facilities and experienced technical staff. We ensure that every sample is handled with utmost care from receipt through analysis to reporting.

The AOAC 991.20 method's accuracy and reliability are crucial for ensuring product safety, preventing cross-contamination during production, and supporting accurate labeling. This ensures that products are safe for consumers with milk allergies or lactose intolerance and helps maintain consumer confidence.

Eurolab Advantages

Our laboratory offers several advantages when it comes to providing AOAC 991.20 milk allergen detection services in chocolate:

  • Accurate Results: Our experienced staff and advanced facilities ensure precise and accurate results, which are critical for maintaining product safety.
  • Compliance Assurance: By adhering strictly to the AOAC 991.20 standard, we help clients meet regulatory requirements and maintain compliance with international food safety standards.
  • Expertise in Chocolate Analysis: Our laboratory has extensive experience analyzing complex chocolate matrices, providing reliable results across different product types.
  • Consistency: We ensure consistent and reproducible results by following standardized procedures for sample preparation and analysis.
  • Customer Support: Our dedicated customer support team is available to answer questions and provide guidance throughout the testing process.
  • Prompt Reporting: Results are provided promptly, allowing clients to make informed decisions about their products.
  • Comprehensive Reporting: Detailed reports include sample identification, detection limits, and compliance status based on specified regulatory requirements.

The combination of these advantages ensures that our clients receive the highest quality service and results, which are essential for maintaining product safety and compliance with international food safety regulations.

Frequently Asked Questions

Is AOAC 991.20 the most accurate method for detecting milk allergens in chocolate?
Yes, AOAC 991.20 is recognized as one of the most accurate methods for detecting milk casein and whey proteins in food products due to its high specificity and sensitivity.
How long does it take to receive results using AOAC 991.20?
Typically, results are available within 5-7 business days from sample receipt. However, this can vary depending on the complexity of the sample and any necessary additional tests.
Can AOAC 991.20 detect milk allergens in all types of chocolate?
Yes, the method has been validated for a wide range of chocolate samples, including milk chocolate, dark chocolate, and white chocolate.
What is the detection limit for AOAC 991.20?
The method can detect milk allergens down to trace levels, typically in the parts per million (ppm) range.
Is the AOAC 991.20 method suitable for small chocolate manufacturers?
Absolutely. The method is versatile and can be applied to samples of all sizes, ensuring that even smaller manufacturers can benefit from accurate allergen detection.
How does the AOAC 991.20 method ensure product safety?
By accurately detecting milk allergens at trace levels, this method helps prevent cross-contamination during production and supports accurate labeling, ensuring that products are safe for consumers with lactose intolerance or milk allergies.
What equipment is used in the AOAC 991.20 method?
The method primarily utilizes solid-phase extraction cartridges and immunoassay-based detection systems, including ELISA plates and spectrophotometers for quantification.
Can I request additional testing beyond the AOAC 991.20 method?
Yes, we offer a range of additional tests to complement the AOAC 991.20 method, including allergen profiling and cross-reactivity studies.

How Can We Help You Today?

Whether you have questions about certificates or need support with your application,
our expert team is ready to guide you every step of the way.

Certification Application

Why Eurolab?

We support your business success with our reliable testing and certification services.

Partnership

Partnership

Long-term collaborations

PARTNER
Excellence

Excellence

We provide the best service

EXCELLENCE
On-Time Delivery

On-Time Delivery

Discipline in our processes

FAST
Security

Security

Data protection is a priority

SECURITY
Care & Attention

Care & Attention

Personalized service

CARE
<