ISO 11905-1 Total Nitrogen Determination

ISO 11905-1 Total Nitrogen Determination

ISO 11905-1 Total Nitrogen Determination

The ISO 11905-1 standard is a widely recognized method for determining total nitrogen in water and wastewater samples. This service is essential for quality managers, compliance officers, R&D engineers, and procurement teams who need accurate measurement of total nitrogen to ensure regulatory compliance and protect environmental standards.

The method described by ISO 11905-1 involves the use of a flow injection analyzer (FIA) system or continuous flow analyzer (CFA). The process begins with the collection of water samples, which are then treated to remove interfering components such as phosphate and chloride ions. This treatment is critical for ensuring accurate results.

The total nitrogen content is determined through the oxidation of ammonia to nitrite by a catalytic converter, followed by conversion to nitrate using a suitable oxidant (such as sodium hypochlorite). The resulting nitrate is then reduced back to nitrite via a catalyst and measured spectrophotometrically. This method provides a precise measurement of total nitrogen, which includes ammonia, organic nitrogen compounds, and inorganic nitrates.

Our laboratory adheres strictly to the ISO 11905-1 standard, ensuring that our results are reliable and repeatable. We use state-of-the-art FIA systems and CFA instruments to provide accurate measurements of total nitrogen content. Our experienced team of analysts is dedicated to delivering high-quality results in a timely manner.

The importance of this test cannot be overstated. Total nitrogen levels can have significant impacts on aquatic ecosystems, human health, and the environment. By providing accurate measurements, we help our clients ensure compliance with local and international regulations such as those set by the Environmental Protection Agency (EPA) in the U.S., or similar bodies worldwide.

Our laboratory is equipped to handle a wide range of sample types, from industrial wastewater to municipal effluent. We pride ourselves on offering a comprehensive service that includes specimen preparation, analysis, and reporting. Our expertise extends beyond just ISO 11905-1; we also offer other water quality testing services such as pH measurement, dissolved oxygen determination, and more.

Scope and Methodology

Step Action Description
1 Sample Collection Collect water samples from the source of interest, ensuring proper preservation and handling.
2 Treatment Remove interfering compounds such as phosphate and chloride ions using a suitable chemical treatment method.
3 Oxidation Oxidize ammonia to nitrite using a catalytic converter at an appropriate temperature.
4 Reduction Convert nitrate back to nitrite for spectrophotometric measurement.
5 Spectrophotometry Determine the absorbance of nitrite at a specific wavelength and calculate total nitrogen content.

Benefits

  • Achieve regulatory compliance with local and international standards.

  • Ensure environmental protection by accurately measuring total nitrogen levels.

  • Promote sustainable practices within industrial processes through precise monitoring of water quality.

  • Enhance safety for workers and the public by identifying potential risks associated with high levels of total nitrogen.

  • Support R&D efforts in developing more efficient waste treatment methods.

  • Enable procurement teams to make informed decisions regarding water quality management systems.

Eurolab Advantages

Our laboratory offers several advantages when it comes to ISO 11905-1 total nitrogen determination:

  • State-of-the-art equipment and software ensure precise measurements.

  • A highly experienced team of analysts provides accurate results in a timely manner.

  • We offer comprehensive specimen preparation services to ensure sample integrity.

  • Our laboratory is accredited by ISO/IEC 17025, ensuring the highest standards of quality and reliability.

  • We provide detailed reports that include all relevant data for easy interpretation.

Frequently Asked Questions

What is the ISO 11905-1 standard?
ISO 11905-1 is an international standard that specifies a method for determining total nitrogen in water and wastewater samples. It ensures accuracy, precision, and reliability of results.
What equipment is used in the ISO 11905-1 test?
The test uses a flow injection analyzer (FIA) or continuous flow analyzer (CFA), along with spectrophotometric instruments for measurement.
How long does the ISO 11905-1 test take?
The entire process typically takes around 2 to 3 hours, from sample preparation to final analysis and reporting.
What are some common sources of interference in the ISO 11905-1 test?
Interfering substances such as phosphate and chloride ions can affect the accuracy of the results. Proper treatment is necessary to eliminate these interferences.
How do you ensure compliance with ISO/IEC 17025 accreditation?
We maintain strict quality control measures and undergo regular audits to ensure that our laboratory meets the highest standards of accuracy and reliability.
What kind of reports do you provide after completing an ISO 11905-1 test?
Our reports include detailed data, charts, and graphs that allow for easy interpretation of the results. They also contain recommendations based on the findings.
Can you perform this test on any type of water sample?
Yes, we can analyze a wide variety of water samples, including industrial wastewater and municipal effluent.
How does ISO 11905-1 compare to other nitrogen determination methods?
ISO 11905-1 offers a standardized approach that is widely recognized and accepted, ensuring consistency in results across different laboratories.

How Can We Help You Today?

Whether you have questions about certificates or need support with your application,
our expert team is ready to guide you every step of the way.

Certification Application

Why Eurolab?

We support your business success with our reliable testing and certification services.

Innovation

Innovation

Continuous improvement and innovation

INNOVATION
Justice

Justice

Fair and equal approach

HONESTY
Security

Security

Data protection is a priority

SECURITY
On-Time Delivery

On-Time Delivery

Discipline in our processes

FAST
Quality

Quality

High standards

QUALITY
<