ASTM E1614 Multi Element Analysis by ICP MS in Environmental Samples Test
The ASTM E1614 standard provides a precise and accurate method for multi-element analysis of trace elements, heavy metals, and other critical species in environmental samples. This service is crucial for understanding the elemental composition and potential contamination levels in various environmental media such as soil, water, air particulates, and biota.
Our laboratory uses Inductively Coupled Plasma Mass Spectrometry (ICP-MS) to perform this analysis. ICP-MS is known for its high sensitivity and selectivity, making it ideal for detecting trace amounts of elements down to parts per billion levels in environmental samples. This method ensures accurate quantification of over 70 elements across a wide range of concentrations.
The ASTM E1614 procedure covers the determination of approximately 45 different elements including arsenic (As), cadmium (Cd), chromium (Cr), copper (Cu), lead (Pb), mercury (Hg), nickel (Ni), selenium (Se), and many others. The standard specifies detailed procedures for sample preparation, digestion, and injection into the ICP-MS instrument.
Our team of experts ensures compliance with ASTM E1614 by following strict protocols that include:
- Proper sample collection and preservation to avoid contamination
- Safe handling and transport of samples to our laboratory
- Standardized digestion processes using appropriate acids like nitric acid (HNO₃) or perchloric acid (HClO₄)
- Precise calibration of the ICP-MS instrument with certified reference materials
- Stringent quality control measures to ensure data accuracy and reliability
The results from ASTM E1614 are reported in parts per million (ppm) or micrograms per liter (µg/L), depending on the sample matrix. These values provide critical insights into environmental contamination levels, which is essential for regulatory compliance, risk assessment, and remediation efforts.
Real-world applications of this test include:
- Monitoring industrial discharge impacts on local water bodies
- Evaluating soil quality in agricultural areas adjacent to mining operations
- Assessing air particulate contamination from urban traffic sources
- Investigating biological uptake of heavy metals by plants and animals
The accuracy and reliability of ASTM E1614 results are paramount for stakeholders who need to ensure compliance with environmental regulations and protect public health. Our laboratory adheres strictly to the ASTM E1614 standard, ensuring that every test is conducted under controlled conditions and reported accurately.
Element | Detection Limit (ppb) | Calibration Range (ppm) | Repeatability (%RSD) |
---|---|---|---|
Boron (B) | 0.1 | 1-500 | 2 |
Cadmium (Cd) | 0.01 | 0.1-500 | 3 |
Copper (Cu) | 0.1 | 0.5-200 | 4 |
Lead (Pb) | 0.05 | 0.5-500 | 5 |
Mercury (Hg) | 0.01 | 0.1-200 | 3 |
Element | Detection Limit (ppb) | Calibration Range (ppm) | Repeatability (%RSD) |
---|---|---|---|
Nickel (Ni) | 0.1 | 0.5-200 | 4 |
Selenium (Se) | 0.05 | 0.5-200 | 3 |
Zinc (Zn) | 0.1 | 0.5-200 | 4 |
Iron (Fe) | 0.5 | 2-800 | 3 |
The precision and accuracy of our testing services are backed by rigorous internal quality assurance processes, ensuring that every result is reliable and actionable. Our goal is to provide you with the highest level of service and support in your environmental testing needs.
Scope and Methodology
The ASTM E1614 multi-element analysis by ICP-MS method covers a wide range of elements, including heavy metals commonly found in environmental samples. The scope of this service includes the following:
Element | Description |
---|---|
Boron (B) | A key component in many industrial processes and fertilizers. |
Cadmium (Cd) | A toxic metal that can cause severe health issues if present in high levels. |
Copper (Cu) | Used in various industries including construction, electronics, and water treatment. |
Lead (Pb) | A neurotoxin that poses significant risks to human health. |
Manganese (Mn) | An essential trace element but can be toxic in high concentrations. |
Zinc (Zn) | Important for biological processes and often used as a supplement or in industrial applications. |
The methodology involves several key steps, including sample collection, digestion, and injection into the ICP-MS instrument. Sample preparation is critical to ensure accurate results. Digestion typically uses nitric acid (HNO₃) or perchloric acid (HClO₄), followed by dilution if necessary.
The analysis process follows ASTM E1614 closely, ensuring that all samples are processed under controlled conditions. Calibration is performed using certified reference materials to ensure accurate measurements. Quality control measures include duplicate analyses and blind sample testing.
Results from the ICP-MS instrument are analyzed and reported in parts per million (ppm) or micrograms per liter (µg/L), depending on the sample matrix. These results provide critical insights into environmental contamination levels, which is essential for regulatory compliance, risk assessment, and remediation efforts.
Customer Impact and Satisfaction
The ASTM E1614 multi-element analysis by ICP-MS in environmental samples test has a direct impact on the quality management of companies operating in various sectors. Compliance officers can ensure that their operations are meeting regulatory requirements, while R&D engineers gain valuable insights into the elemental composition of environmental media.
For procurement teams, this service helps identify potential suppliers who adhere to high standards of environmental responsibility. By partnering with a laboratory that offers ASTM E1614 services, customers benefit from:
- Avoidance of legal penalties associated with non-compliance
- Improved reputation and trust among stakeholders
- Enhanced product quality through accurate elemental analysis
- Faster decision-making in procurement processes
We prioritize customer satisfaction by providing clear, concise reports that meet or exceed ASTM E1614 standards. Our team of experts ensures that each test is conducted under controlled conditions and reported accurately. Feedback from satisfied customers highlights the reliability and accuracy of our services.
Our commitment to excellence has earned us a reputation as a trusted partner for environmental testing. We are proud to offer this service, which plays a crucial role in protecting public health and the environment.
Environmental and Sustainability Contributions
The ASTM E1614 multi-element analysis by ICP-MS in environmental samples test contributes significantly to sustainable practices. By accurately determining the presence and concentration of heavy metals, this service helps prevent contamination of soil, water, air, and biota.
Through our testing, we enable stakeholders to:
- Identify sources of pollution and take corrective actions
- Evaluate the effectiveness of remediation efforts
- Ensure compliance with environmental regulations
- Maintain clean air and water quality standards
The results from this service can be used to develop mitigation strategies, reduce environmental impact, and promote sustainable practices. By providing accurate data on elemental composition, we contribute to a healthier planet and protect future generations.
We are committed to reducing our own environmental footprint by implementing energy-efficient practices and using environmentally friendly laboratory procedures. Our services not only help our clients achieve their sustainability goals but also play a crucial role in the broader effort to protect the environment.